200 research outputs found

    Discrete differential operators on polygonal meshes

    Get PDF
    Geometry processing of surface meshes relies heavily on the discretization of differential operators such as gradient, Laplacian, and covariant derivative. While a variety of discrete operators over triangulated meshes have been developed and used for decades, a similar construction over polygonal meshes remains far less explored despite the prevalence of non-simplicial surfaces in geometric design and engineering applications. This paper introduces a principled construction of discrete differential operators on surface meshes formed by (possibly non-flat and non-convex) polygonal faces. Our approach is based on a novel mimetic discretization of the gradient operator that is linear-precise on arbitrary polygons. Equipped with this discrete gradient, we draw upon ideas from the Virtual Element Method in order to derive a series of discrete operators commonly used in graphics that are now valid over polygonal surfaces. We demonstrate the accuracy and robustness of our resulting operators through various numerical examples, before incorporating them into existing geometry processing algorithms

    Weighted Triangulations for Geometry Processing

    Get PDF
    In this article we investigate the use of weighted triangulations as discrete, augmented approximations of surfaces for digital geometry processing. By incorporating a scalar weight per mesh vertex, we introduce a new notion of discrete metric that defines an orthogonal dual structure for arbitrary triangle meshes and thus extends weighted Delaunay triangulations to surface meshes. We also present alternative characterizations of this primal-dual structure (through combinations of angles, areas, and lengths) and, in the process, uncover closed-form expressions of mesh energies that were previously known in implicit form only. Finally, we demonstrate how weighted triangulations provide a faster and more robust approach to a series of geometry processing applications, including the generation of well-centered meshes, self-supporting surfaces, and sphere packing

    Tianfenicol no tratamento do cancroide. Estudo de 1.128 casos

    Get PDF
    Thiamphenicol, an aminic derivate of hydrocarbilsulfonil propandiol, was used for the treatment of 1,171 chancroid bearing patients. Each patient was medicated with 5.0 g of granulated thiamphenicol, orally, in a single dose, and was reevaluated 3, 7 and 10 days after the treatment. Ten patients (0.89%) did not respond to the proposed treatment. 133 patients presented healed ulcers after 3 days of treatment, 976 patients healed chancres on the seventh day after the treatment, and 39 patients took 10 days to present healed chancres. The results of this study indicate that the rate of patients that were cured, the low incidence of side effects, and the practicality of administration make of thiamphenicol an excellent choice for the treatment of chancroid.O tiamfenicol, derivado amínico do hidrocarbilsulfonil propandiol, foi utilizado para o tratamento de 1.171 pacientes portadores de cancróide. Cada paciente foi medicado com 5,0 g de tianfenicol granulado, via oral e em dose única, sendo reavaliados após 3, 7 e 10 dias do tratamento. Dez pacientes (0,89%) não responderam à terapêutica proposta; 133 pacientes apresentaram úlceras cicatrizadas após 3 dias do tratamento; 976 pacientes apresentaram lesões cicatrizadas no sétimo dia após o tratamento e, 39 pacientes levaram 10 dias para apresentarem lesões cicatrizadas. Os resultados deste estudo indicam que o índice de cura, a baixa incidência de efeitos colaterais, e a praticidade de administração fazem hoje do tianfenicol uma excelente escolha no tratamento do cancróide

    Space-time editing of elastic motion through material optimization and reduction

    Get PDF
    We present a novel method for elastic animation editing with space-time constraints. In a sharp departure from previous approaches, we not only optimize control forces added to a linearized dynamic model, but also optimize material properties to better match user constraints and provide plausible and consistent motion. Our approach achieves efficiency and scalability by performing all computations in a reduced rotation-strain (RS) space constructed with both cubature and geometric reduction, leading to two orders of magnitude improvement over the original RS method. We demonstrate the utility and versatility of our method in various applications, including motion editing, pose interpolation, and estimation of material parameters from existing animation sequences

    Correlation between margin fit and microleakage in complete crowns cemented with three luting agents

    Get PDF
    Microleakage can be related to margin misfit. Also, traditional microleakage techniques are time-consuming. This study evaluated the existence of correlation between in vitro margin fit and a new microleakage technique for complete crowns cemented with 3 different luting agents. Thirty human premolars were prepared for full-coverage crowns with a convergence angle of 6 degrees, chamfer margin of 1.2 mm circumferentially, and occlusal reduction of 1.5 mm. Ni-Cr cast crowns were cemented with either zinc phosphate (ZP) (S.S. White), resin-modified glass-ionomer (RMGI) (Rely X Luting Cement) or a resin-based luting agent (RC) (Enforce). Margin fit (seating discrepancy and margin gap) was evaluated according to criteria in the literature under microscope with 0.001 mm accuracy. After thermal cycling, crowns were longitudinally sectioned and microleakage scores at tooth-cement interface were obtained and recorded at ×100 magnification. Margin fit parameters were compared with the one-way ANOVA test and microleakage scores with Kruskal-Wallis and Dunn's tests (alpha=0.05). Correlation between margin fit and microleakage was analyzed with the Spearman's test (alpha=0.05). Seating discrepancy and marginal gap values ranged from 81.82 µm to 137.22 µm (p=0.117), and from 75.42 µm to 78.49 µm (p=0.940), respectively. Marginal microleakage scores were ZP=3.02, RMGI=0.35 and RC=0.12 (p;0.05). Conclusion: Margin fit parameters and microleakage showed no strong correlations; cast crowns cemented with RMGI and RC had lower microleakage scores than ZP cement

    Avaliação em MEV do padrão de condicionamento do esmalte dental promovido por monômeros ácidos e o ácido fosfórico

    Get PDF
    ABSTRACT OBJECTIVE: Although self-etching bonding systems (SES) are indicated to prepare dental enamel for bonding, concerns have been expressed regarding their effectiveness. The aim of this study was to analyze the etching pattern (EP) of nine SES in comparison with 35% and 34% phosphoric acid etchants (FA) on intact (IN) and ground (GR) enamel surface. MATERIALS AND METHODS: Twenty-two human third molars were sectioned in mesial-distal and buccal-lingual directions, and four dental fragments were obtained from each tooth. Half of the fragments were ground using 600-grit SiC paper and the other half remained intact. The fragments were randomly assigned into 22 groups, according to the texture of enamel surface (IN and GR) and the technique to etch the enamel (34% FA, 35% FA, AdheSE primer; Brush & Bond; Clearfil Protect Bond primer; iBond; One-up Bond F; OptiBond Solo Plus primer; Tyrian SPE primer; Unifil Bond primer and Xeno III). Conditioners were applied to IN and GR enamel surfaces, according to the manufacturer's instructions. Specimens etched with phosphoric acids were washed with water, while the surfaces treated with SES were submitted to alternate rinsing with alcohol and acetone. The specimens were dried, sputter-coated and examined under a scanning electron microscope. RESULTS: For both IN and GR enamel surfaces, the EP of 34 and 35% FA was deeper and more homogeneous in comparison to EP of SES, except for Tyrian SPE. The acidic monomer action of self-etching systems was more effective on GR enamel. CONCLUSION: Most of the SES are less aggressive than phosphoric acid etchants and their etching effects were reduced on intact enamel surfaces.OBJETIVO: Apesar dos sistemas adesivos autocondicionantes (SAA) serem indicados para aplicação no esmalte dental, preocupação tem sido relatada com relação a sua efetividade. O objetivo deste estudo foi avaliar o padrão de condicionamento ácido (PCA) promovido por nove SAA e comparar ao PCA produzido pelo ácido fosfórico (35% e 34% - AF) no esmalte intacto (EI) ou abrasionado (EA). MATERIAIS E MÉTODOS: Vinte e dois terceiros molares humanos foram seccionados nos sentidos mésio-distal e vestíbulo-lingual, e quatro fragmentos dentais foram obtidos a partir de cada dente. Metade dos fragmentos tiveram o esmalte abrasionado com lixas de SiC (600) e a outra metade permaneceu intacta. Os fragmentos foram divididos em 22 grupos, de acordo com a textura da superfície do esmalte (EI e EA) e a técnica de condicionar o esmalte (AF 34 %, AF 35%, AdheSE primer; Brush & Bond; Clearfil Protect Bond primer; iBond; One-up Bond F; OptiBond Solo Plus primer; Tyrian SPE primer; Unifil Bond primer e Xeno III). Os agentes condicionadores foram aplicados nos EI e EA, de acordo com as instruções dos fabricantes. Espécimes tratados com AF foram lavados com água, enquanto os dentes tratados com SAA foram tratados com banhos alternados de álcool e acetona. Os espécimes foram secos, metalizados e observados em microscopia eletrônica de varredura. RESULTADOS: Em ambas as superfícies (EI e EA), o PCA dos AF (34 e 35%) foi mais profundo e homogêneo, quando comparados ao PCA produzido pelos SAA, exceto para o adesivo Tyrian SPE. A ação dos monômeros ácidos dos SAA foi mais efetiva no EA. CONCLUSÃO: A maioria dos SAA é menos agressiva que o ácido fosfórico e seus efeitos condicionadores são reduzidos em superfícies de EI

    Estatuto de Museus, Comunicação e Museus de Tribunais Superiores do Judiciário no Brasil

    Get PDF
    This article sought to verify whether museums located in higher courts (STF, STJ, STM, TSE and TST) have been followed or not the guidelines established by the Statute of Museums, Law 11.904/2009, especially about communication matters. This research was guided in accordance to methodology of Depth Hermeneutics, initially developed by Thompson (1995). Using some articles of the Law as a parameter of analysis, it was possible to conclude that although in force for nine years, the Statute has not been effectively complied by the institutions linked to the Judiciary.Este artigo buscou verificar se museus localizados em tribunais superiores (STF, STJ, STM, TSE e TST) têm levado em conta ou não as diretrizes previstas pelo Estatuto de Museus, Lei 11.904/2009, principalmente no que se refere às atividades ligadas à comunicação. Para isso, a pesquisa utilizou a metodologia da Hermenêutica de Profundidade, desenvolvida inicialmente por Thompson (1995). Utilizando alguns artigos da lei como parâmetro de análise, foi possível, concluir que embora em vigor há nove anos, o Estatuto não tem sido efetivamente cumprido pelas próprias instituições ligadas ao Poder Judiciário

    Evaluation of depth of cure and Knoop hardness in a dental composite photo-activated using different methods

    Get PDF
    The aim of this study was to evaluate the depth of cure and Knoop hardness in the P60 composite resin photo-activated using different methods. A bipartite brass matrix (3 mm in diameter X 11 mm in height) was filled with the composite and photo-activation was performed using continuous light, exponential light, intermittent light, plasma arc curing (PAC) or light-emitting diodes (LED). After opening the matrix, the uncured material was removed with a steel spatula and the polymerized composite was measured using a pachymeter. The specimens were then included in self-curing acrylic resin and worn longitudinally and the hardness was measured on the surface and at depths of 1, 2, 3, 4 and 5 mm. The data were analyzed by ANOVA and Tukey's test (5%). The results showed that the depth of cure was higher with the intermittent light, followed by continuous light, exponential light, PAC and LED methods. Up to a depth of 2 mm, all methods revealed similar hardness values, but there were differences between them at other depths, at which LED demonstrated the lowest values followed by PAC.O objetivo deste trabalho foi avaliar a profundidade de polimerização e a dureza Knoop do compósito restaurador P60 fotoativado por diferentes métodos. Uma matriz metálica bipartida (3 mm de diâmetro X 11 mm de altura) foi preenchida com o compósito e fotoativada através da luz contínua, luz exponencial, luz intermitente, plasma de xenônio (PAC) ou luz emitida por diodo (LED). Após a abertura da matriz, o material não polimerizado foi removido com o auxílio de uma espátula metálica e o compósito polimerizado medido com um paquímetro digital. Então os espécimes foram incluídos em resina acrílica autopolimerizável e desgastados longitudinalmente e a dureza foi medida na superfície e nas profundidades de 1, 2, 3, 4 e 5 mm. Os dados foram analisados por ANOVA e teste de Tukey (5%). Os resultados mostraram que a profundidade de polimerização foi maior com a luz intermitente, seguida pela luz contínua, luz exponencial, PAC e LED. Até a profundidate de 2 mm, todos os métodos de fotoativação revelaram valores de dureza similares, porém diferiram a outras profundidades, onde o LED demonstrou os menores valores, seguido pelo PAC.19920

    Efeito do uso de forradores resinosos sobre a microinfiltração de restaurações classe V em compósito odontológico

    Get PDF
    OBJETIVO: O objetivo desse estudo foi avaliar os efeitos da aplicação de um adesivo em diferentes espessuras ou em associação com um adesivo com carga ou com compósito de baixa viscosidade na microinfiltração marginal de restaurações com compósito odontológico. MÉTODOS: Quarenta incisivos bovinos foram selecionados e cavidades circulares (4mm de diâmetro X 2mm de profundidade) foram preparadas na região da junção cemento-esmalte. Os dentes foram então divididos em quatro grupos de acordo com o forramento utilizado: 1: (controle) aplicação do sistema de união Scotchbond Multi Uso (SBMU) - 1 camada de adesivo; 2: aplicação de 3 camadas do adesivo SBMU; 3: aplicação do SBMU, seguido pela aplicação de uma camada do adesivo Optibond FL; 4: aplicação do SBMU seguido pela aplicação de forramento com o compósito de baixa viscosidade Flow-it. Todas as cavidades foram restauradas com o compósito Z100. O teste de microinfiltração foi conduzido de acordo com a ISO (TR11405). Os dados foram analisados pelo teste de Kruskall-Wallis (p>;0,05). RESULTADOS: O grupo 4 apresentou redução significativa dos níveis de infiltração quando comparado ao grupo 1. Os grupos 2 e 3 apresentaram valores intermediários e não foram detectadas diferenças significativas quando estes grupos foram comparados aos grupos 1 e 4. CONCLUSÃO: O uso de forramento com compósito de baixa viscosidade pode reduzir os níveis de infiltração marginal, possibilitando melhora na qualidade das restaurações em compósito odontológico.PURPOSE: The aim of this study was to evaluate the effect of an adhesive applied in layers of different thickness or in association with a filled adhesive or with a low viscosity composite liner on the microleakage of composite restorations. METHODS: Forty bovine incisors were prepared with round cavities (4mm diameter X 2mm depth) on the cementoenamel junction. The teeth were assigned to four groups according to the liner used: 1 (control) - application of 1 layer of the Scotchbond Multi Purpose adhesive system (SBMP); 2 - application of 3 layers of SBMP; 3 - application of 1 layer of SBMP followed by application of one layer of Optibond FL adhesive; 4 - application of one layer of SBMP followed by application of flowable composite Flow-it. All cavities were restored using composite resin Z100. The microleakage test was conducted according to ISO (TR11405). Data were analyzed by Kruskall-Wallis test (a=0.05). RESULTS: Group 4 showed less leakage than Group 1. Groups 2 and 3 showed intermediate values and there were no statistical differences when they were compared to the values of Groups 1 and 4 CONCLUSION: The use of resin liners with flowable composites can reduce the microleakage of composite restorations

    Comparison of in vivo and in vitro models to evaluate pulp temperature rise during exposure to a Polywave® LED light curing unit

    Get PDF
    Objectives: To measure and compare in vivo and in vitro pulp temperature (PT) increase (ΔTEMP) over baseline, physiologic temperature using the same intact upper premolars exposed to the same Polywave® LED curing light. Methodology: After local Ethics Committee approval (#255,945), local anesthesia, rubber dam isolation, small occlusal preparations/minute pulp exposure (n=15) were performed in teeth requiring extraction for orthodontic reasons. A sterile probe of a temperature measurement system (Temperature Data Acquisition, Physitemp) was placed within the pulp chamber and the buccal surface was sequentially exposed to a LED LCU (Bluephase 20i, Ivoclar Vivadent) using the following exposure modes: 10-s low or high, 5-s Turbo, and 60-s high. Afterwards, the teeth were extracted and K-type thermocouples were placed within the pulp chamber through the original access. The teeth were attached to an assembly simulating the in vivo environment, being similarly exposed while real-time temperature (°C) was recorded. ΔTEMP values and time for temperature to reach maximum (ΔTIME) were subjected to two-way ANOVA and Bonferroni's post-hoc tests (pre-set alpha 0.05). Results: Higher ΔTEMP was observed in vitro than in vivo. No significant difference in ΔTIME was observed between test conditions. A significant, positive relationship was observed between radiant exposure and ΔTEMP for both conditions (in vivo: r2=0.917; p<0.001; in vitro: r2=0.919; p<0.001). Conclusion: Although the in vitro model overestimated in vivo PT increase, in vitro PT rise was close to in vivo values for clinically relevant exposure modes
    corecore